Model: I.T. E DESK TOP F11503-X SERIES 150W |
Feature:
1.Universal Input
2.IEC320 Receptacle 3P (C14)
3.Optional Output Connector
4.OVP, OCP, OPP, Auto Recovery
5.CEC/ EUP efficiency level compliance up to Level 5
6.Size: 168*71*37.5mm
7.Low cost
8.Safety agency approval by CB-Nemko/GS/FCC/CE/UL/CCC/LVD/PSE
9.Design to meet safety standard EN60950-1 I.T.E
10.Rohs compliance
Specifications: Parameter Description/SPEC.: Input Voltage: Inrush Current:. Dielectric Withstand Input/ Output : MTBF: Leakage current: Efficiency: No Load Stand by power: Hold Up Time: Output Voltage: Ripple & Noise: Regulation: Operating Temperature: Storage Temperature: Protections: Safety standard: EMC standard: Standard output connector: Standard output cable length: Optional output connecter type: |
100 ~ 240 VAC +/-10% 50A at 115VAC/ 100A at 230VAC max. 3000 VAC 50000 hrs < 0.75mA >= 85% type. for CEC requirement <2W @ 230 VAC 10mS at Nominal Line DC 12~13V Single output 2% p-p max Load ± 5% max -10 °C ~ +50 °C (derating linearly from 100% load @ 40 °C to 75% load @ 50 °C) -20 to +85°C OCP, OVP,OPP (Over Power & Short circuit) IEC/UL/EN60950-1, CE, CB ,CCC EN55022(CISPR 22) class B, FCC class B Options UL1185, #14AWG/ 4Ft. Min din/ Pennell mount / Water proof / Molex |
Available labeling ratings
Part no./(customer code) | Voltage | Ampere |
F11503-E(C14-12xxx) | 12V | 12.50A |
F11503-E(C14-13xxx) | 13V | 11.53A |